Pecoware Thermostat TC170 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
WIRING DIAGRAM
© COPYRIGHT 2008 PECO, INC. ALL RIGHTS RESERVED. P/N 69289 3220-2083 REV 0 PAGE 3
OUTPUT CONFIGURATION
A table is provided on the inside of the base to docu-
ment the function of various outputs. The function of
congurable outputs should be lled in when the unit is
installed.
JP4 JUMPER SELECTION
This jumper is temporarily installed at initial power
up to recongure outputs 3 through 6. See Output
Conguration.
JP3 JUMPER SELECTION
This jumper is shipped normally open. Placement
of a jumper onto both pins allows for Occupancy
Detection/ Door switch and Door Switch Only
Operation.
JP1 JUMPER SELECTION
Removing this jumper allows the sensor to be lo-
cated in a remote location. Accessory remote probe
sensors are available in standard 60” lengths but
can be extended to meet application requirements.
SWITCH
24 V
110-
277V
HIGH -VOL TAGE - REMOVE POWER BEFORE SER VICING
CAUTION:
JP 1
JP 3
JP 4
JP1 JUMPER
JP3 JUMPER
JP4 JUMPER
CIRCUIT BOARD
In Cover
SWITCH POSITION
This switc h i s p laced in the 24V positio n a t the
factor y. Thi s t hermostat will not functio n
properly if located in 110-277V positio n
INPUT
VOLTAGE
OUTPUT RA TINGS
24 VAC
PILOT
DUTY
24 VA
VOLTAGE
24 VAC
Page view 2
1 2 3 4

Comments to this Manuals

No comments